Beurer Infrared Heat Lamp IL60

Catalogue price. Delivery and final availability will be confirmed by IASIMO. No online payment is collected.

Ask about this product

Product information

Beurer Infrared Heat Lamp IL60 Infrared heat can help relax your muscles and promote circulation, making it a popular treatment method with physiotherapists to help ease tension and improve range of movement. The effects of infrared heat are also known to relieve the symptoms of a cold by working to reduce inflammation in the nasal passages and clear clogged mucus. The IL60 Infrared Heat Therapy Lamp from Beurer enables you to benefit from infrared therapy in the comfort of your own home. It boasts a large radiation area and adjustable position for comfortable treatment on even the most awkward areas. It has an adjustable timer with countdown display and automatic switch-off when your treatment is finished. Key Features: • 30cm x 40cm heat radiation field • Adjustable angle of 0-40 degrees • Digital treatment time (1-15min) Product Specifications: • Overheat protection • Includes protective eyewear
Brand
Beurer
Product code
IAS-LGT-BEU-0175
All Boots Sub-categories
light therapy, wake up & SAD lights
Product Type
light therapy
Rating (/5)
4.38
Reviews
21
Boots Item Code
10366894
Country of Origin
Hungary
How to Use
1. Hold the protective eyewear to your eyes and pull the rubber band over your head. You can adjust the rubber band individually. 2. Press the ON/OFF switch 5 to switch on the device. The device switches on automatically after a short time. The remaining time display 4 shows 15 minutes as the duration of treatment. 3. Use the time selection button 3 to select the desired treatment duration (1 to 15 minutes). The set treatment duration is displayed in the remaining time display 4 . You can also change the duration of treatment after it has started using the time selection button 3 . 4. After the set treatment duration has elapsed, the device switches off automatically. To stop the treatment early, press the ON/OFF switch 5 .
Hazards & Cautions
• Always use the supplied protective eyewear during treatment. • Monitor the area of the body being irradiated and the reaction of the skin regularly. Should signs of hypersensitivity or allergic reactions occur, cease radiation immediately and consult a doctor. • Risk of burns! During treatment, never touch the hot glass pane 2. • Any form of improper use can be dangerous. • To avoid the risk of electric shock or permanent damage to the device, check that the voltage specified on the device corresponds to the local mains voltage before connecting the device. • Use a mains connection that is easily accessible so that the mains plug can be removed quickly if necessary. • Do not touch the mains plug with wet hands as there is a risk of electric shock! • Arrange the mains cable so that no-one will trip over it. • Always remove the mains plug from the socket when the device is not in use, when you are cleaning the device, or in the event of disruptions, smoke, or odour formation. When removing the plug, pull on the mains plug, not on the cable! • Caution when handling the mains cable (risk of strangulation and suffocation). • Before use, ensure that the device and included components display no visible damage. If you have any doubts, do not use the device and contact your retailer or the specified Customer Services address. This is particularly applicable in the case of scratches and cracks in the glass pane or cracks in the housing. • If the mains cable or its housing is damaged, this must be replaced by Customer Services or the retailer, as there is a risk of electric shock. • Disconnection from the power supply network is only guaranteed if the mains plug is unplugged. • If the mains cable of this device is damaged, it must be disposed of. If it cannot be removed, the device must be disposed of. • Never wrap the mains cable around the infrared lamp. • Risk of burns! The filter pane and the device housing heat up considerably during operation. Risk of burns when touched! • Do not touch the hot glass pane when using the buttons (ON/ OFF and timer). There is a risk of burns when doing so. • Always allow the device to cool before touching it. • Always remove the mains plug and allow the device to cool before packing it away. • Do not touch the device with damp hands while it is switched on. • Water and electricity represent a dangerous combination! To avoid the risk of electric shock: - Do not use this device in a wet environment (e.g. in the bathroom or near a shower or swimming pool). - Do not allow water to run into the device. - Do not allow water to spray onto the device. - Only operate the device if it is completely dry.
Important Info / Manufacturer
Country of Origin: Hungary Address: UK: Beurer UK Limited, Suite 16 Stonecross Place, Stonecross Lane North, Lowton, WA3 2SH www.beurer.com